Abx Micros 60 Hematology Analyzer for Sale. Check out our extensive catalog of New & Used Abx Micros 60 Hematology Analyzer devices. More than 200,000 items of. The ABX MICROS 60-CS/CT is a fully automated (Microprocessor controlled) Hematology analyzer used for in-vitro diagnostics testing of Whole Blood specimens, Platelet PRP samples, and Whole Blood component concentrates. The ABX MICROS 60-CS/CT is available in 5, 8, 16, and 18 parameters. These parameters are noted according to the system setup.
ABX Minidil LMG (10L) ABX Miniclean (1L) ABX Alphalyse 360 (0.36L) ABX CRP REA (100 cycles) QUALITY CONTROL / CALIBRATOR: Control: ABX Minotrol CRP (3 levels) Calibrator: ABX Minocal CBC ABX CRP Calibrator POWER REQUIREMENTS: Power supply from 100 Vac to 240 Vac +/- 10% 50 Hz to 60 Hz. Power consumption Maximum 150 VA. OPERATING TEMPERATURE. ABX Micros 60 is a fully automated hematology analyzer from ABX Diagnostics (renamed as Horiba ABX). Horiba ABX Micros 60 is a powerful tool best suited for use in any physician’s office lab, hospitals, and small clinics. ABX Micros 60 is an ideal choice for the determination of 8 or 18 fully automated parameters including HGB, WBC, RBC, MCV.
ABX Micros 60 6 - RAB042FEN - User Manual - ABX Micros 60 Once the Identification has been entered, a message will appear on the LCD display stating «Press the sampling bar», press the manual sampling bar or press the «Startup» key on the front panel of the ABX Micros 60 to start the analysis cycle. Abx micros 60 manual - SlideShare.
- Documents
- Videos
- News
DESCRIPTION
8 or 18 fully automated parametersCBC / 3 Part DIFFOpen or Closed TubeImpedance technology, photometry
Microsampling: Only 10 µL
Smart card based memory storage (optional)
No compressor (stepper motor technology)FORUMSView All (20)
Ask a New Question-frankms123_83002
Replies
5 months ago5 months agoHavingproblem with RDW, Low results Having problems with low RDW results.RBC 5,09-HGB 15,1-HCT 49,3 MCV 97-MCH 29,7 MCHC 30,66 PLT 230 RDW 2,2.
Reply-Mkama zebedayo
a year agoa year agoservicing micro 60 and screen master
i would like to know what can i do to my micro 60 that is giving out high PLT reading that is going up to 22222 sometimes giving DIL.also to my screen master that is giving out a wide range of deviation to a single sample or QC testing sample aslo the failure of QC,How to calibrate this one since it has failed more than fifth times?Reply-Trelaone2
Replies
2 years ago2 years agoSERVICE MANUAL
Dear All,Am looking for a service manual for Horiba ABX Micros 60. May anyone who has it share by sending to: vgmakwinja@medcol.mwThanks in advance.ReplySERVICE COMPANIESView All Hematology Analyzer Companies
FEATURES
Free email software for mac. Measurement methods: Impedance technology, photometry. Liquid valves (without pinching): Reliability and increased precision No compressor (stepper motor): Reliability, less maintenance and noise
Additional Specifications
Technical
Weight
31 lbs
Power supply
90/240 V - 50/60 Hz - 230 VA.
Dimensions
16.5 in x 14 x 12.5 in (HxWxD).
Printer
Dot matrix.
Throughout
60 samples/hour (on open tube)
55 samples/hour (closed tube)
Data management
Automated smart cards used for QC and patient data storage (optional).
RS 232 output.
Mono-directional connection.
Memory
Last result (with curves) or 78 results (optional smart cards based memory)
Screen
2 lines of 40 alphanumerical characters.
Keyboard
Barcode reader (optional).
Samples
60 samples/hour (open tube)
Parameters (16+2)
CBC Mode (18 parameters): WBC, RBC, HGB, HCT, MCV,*RDW, MCH, MCHC, PLT, MPV, PCT, *PDW, % and # of LYM, MON and GRA
Graphics
LMG histogram, RBC, PLT histograms
Sample-Volume
CBC mode : 10 µL
Stability
24 hours (CBC)
Operating sample mode
Open tube mode with 4 position tube holder (QC, 125 or 500 µL, 3 or 5 mL)
Identification
Patient I.D., Sequence#
Flags
Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags
* RUO (Research Use Only)One moment please..Not A Member?Sign Up- Documents
- Videos
- News
DESCRIPTION
8 or 18 fully automated parametersCBC / 3 Part DIFFOpen or Closed TubeImpedance technology, photometry
Microsampling: Only 10 µL
Smart card based memory storage (optional)
No compressor (stepper motor technology)FORUMSView All (20)
Ask a New QuestionHoriba Micros 60 User Manual
-frankms123_83002
Replies
5 months ago5 months agoHavingproblem with RDW, Low results Having problems with low RDW results.RBC 5,09-HGB 15,1-HCT 49,3 MCV 97-MCH 29,7 MCHC 30,66 PLT 230 RDW 2,2.
Reply-Mkama zebedayo
a year agoa year agoservicing micro 60 and screen master
i would like to know what can i do to my micro 60 that is giving out high PLT reading that is going up to 22222 sometimes giving DIL.also to my screen master that is giving out a wide range of deviation to a single sample or QC testing sample aslo the failure of QC,How to calibrate this one since it has failed more than fifth times?Reply-Trelaone2
Replies
2 years ago2 years agoSERVICE MANUAL
Dear All,Am looking for a service manual for Horiba ABX Micros 60. May anyone who has it share by sending to: vgmakwinja@medcol.mwThanks in advance.ReplySERVICE COMPANIESView All Hematology Analyzer Companies
Abx Micros 60 Manual Usuario
FEATURES
Measurement methods: Impedance technology, photometry. Liquid valves (without pinching): Reliability and increased precision No compressor (stepper motor): Reliability, less maintenance and noise
Additional Specifications
Abx Pentra 60
Technical
Weight
31 lbs
Power supply
90/240 V - 50/60 Hz - 230 VA.
Dimensions
16.5 in x 14 x 12.5 in (HxWxD).
Printer
Dot matrix.
Throughout
60 samples/hour (on open tube)
55 samples/hour (closed tube)
Data management
Automated smart cards used for QC and patient data storage (optional).
RS 232 output.
Mono-directional connection.
Memory
Last result (with curves) or 78 results (optional smart cards based memory)
Screen
2 lines of 40 alphanumerical characters.
Keyboard
Barcode reader (optional).
Samples
60 samples/hour (open tube)
Parameters (16+2)
CBC Mode (18 parameters): WBC, RBC, HGB, HCT, MCV,*RDW, MCH, MCHC, PLT, MPV, PCT, *PDW, % and # of LYM, MON and GRA
Graphics
LMG histogram, RBC, PLT histograms
Sample-Volume
CBC mode : 10 µL
Stability
24 hours (CBC)
Operating sample mode
Open tube mode with 4 position tube holder (QC, 125 or 500 µL, 3 or 5 mL)
Identification
Patient I.D., Sequence#
Flags
Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags
* RUO (Research Use Only)